By the time fire takes to penetrate assemblies (walls in hours, doors in minutes)
How are fire‑resistance ratings for commercial construction listed?
| Term | Definition |
|---|---|
By the time fire takes to penetrate assemblies (walls in hours, doors in minutes) | How are fire‑resistance ratings for commercial construction listed? |
Separated from other occupancies with fire‑rated construction | Group H‑4 occupancies must be: |
Radiant Panel Test | Which test applies to upholstered furniture fabrics? |
Automatic Sprinkler System, Fire Alarm System, Standpipe System, Fire Extinguishers, Smoke Control / Exhaust Systems | List active fire suppression systems for a floor plan |
The latch (door‑handle) side | On which side of the door must the manual fire alarm pull station be located? |
To contain fire and prevent its spread | What is the purpose of passive fire protection? |
The temperature increases rapidly at a predetermined rate
| A rate‑of‑rise heat detector responds when: |
Concealed | Which type of sprinkler head is the least visually noticeable? |
Heat | Sprinkler systems are activated by: |
Class I - fire department;
Class II - building occupants;
Class III - both | What are the three standpipe classes and who uses them? |
4 inches | Fire extinguishers must be mounted no more than how far off the wall? |
75 ft | Fire extinguishers must be located no more than how many feet from an occupant? |
True | Sprinkler head spacing of 4 ft to 10 ft in a grid pattern is: True or False |
78 inches | What is the minimum headroom clearance required on ramps and stairs? |
Vertical Flame Test | Which flame‑spread test applies to draperies? |
Steiner Tunnel Test (ASTM E84)
| Which test is typically used for wallcoverings? |
Class B | A Steiner Tunnel Test flame‑spread index of 26-75 corresponds to: |
1 hour | Tenant separation walls must have a minimum fire‑resistance rating of: |
R-3 | A single‑family home falls under which occupancy classification? |
Group F | Industrial manufacturing buildings fall under which occupancy group? |
1:12 | What is the maximum allowable slope for an accessible ramp? |
Fire‑Rated Walls/Fire Barriers, Fire‑Rated Doors & Frames, Fire‑Rated Floor/Ceiling Assemblies, Firestopping at Penetrations(sealants around pipes and ducts), Smoke Barriers and Partitions | List passive fire suppression systems for a floor plan |
Visual and Audible | When adding fire alarms to a building, which types do you need to install to meet ADA standards? |
Particle Beam Detectors | Which type of smoke detector identifies smoke by detecting the presence of particles in the air? |
Heat Detectors | Which type of detector is more effective at identifying large, fast‑growing flaming fires? |